Speaker Box Genius

Box losses (Ql, Qa, Qp): what values should you use?

Ask AI about this page

Every box simulator asks for three loss figures, usually with defaults nobody explains: WinISD's are Ql 10, Qa 100, Qp 100. Forum answers range from "leave them alone" to "use 7, everyone does" to "real boxes are 20". Here's what the three numbers mean, where they come from, what difference they make, and how to find the right ones for your box.

A box in cutaway with small leaks of air escaping through its seams.

Open the example (Ql 10) →

Where the three losses come from

Richard Small's analysis of the vented box describes its losses as three Q values, each measured at the box's tuning frequency [1]:

A lower Q means more loss. A Q of 100 is almost lossless; a Q of 5 is very lossy. The three combine like resistors in parallel into the box's total loss, QB: 1/QB = 1/QL + 1/QA + 1/QP.

In the app the three are in Settings → Simulation → Box (Leak Ql, Absorb Qa, Port Qp); clear a field to leave that loss out altogether (it shows "None"), as textbook alignment tables do. A sealed, ported or passive radiator box can also have its own leakage: in Boxes, open its Leakage row and pick This box, so a tight box and a leaky one can be compared side by side. Stuffing sets a box's own Qa the same way.

What values real boxes have

In most vented boxes leakage is the biggest of the three, which is why simulators usually give only QL a realistic value and set the other two high [1][2]. The history of the classic starting point, QL = 7, goes back to Small's measurements and Beranek's calculations of box Q values in the same range [2]. Measured boxes commonly come out between about QL = 5 and 20: a carefully built, glued and gasketed box at the high end, a box with a leaky driver or a removable back at the low end.

SettingTypical rangeWhat gives a low value
Ql (leakage)5–20 (start at 7–10)Leaky driver (porous dust cap, vented pole), poor seals, removable panels
Qa (absorption)10–100 (100 empty, lower when stuffed)Lots of stuffing, flexing panels
Qp (port)50–100+Small, rough or long ports; high air speeds

Neville Thiele, who first set out the vented-box alignments, noted that leakage has only a small effect in vented designs, and that it can be made up by a slightly larger box and a slightly higher driver Q [3].

How much they matter

The example: a Dayton Audio DSA215-8 in its QB3 ported box, 16.2 L tuned to 39.8 Hz.

Ql (Qa, Qp 100)F3Response at 40 HzImpedance peaks
100 (no leakage)46.6 Hz−5.3 dB31.4 Ω and 30.8 Ω
2048.4 Hz−5.8 dB30.0 Ω and 28.9 Ω
10 (WinISD's default)50.6 Hz−6.4 dB28.6 Ω and 26.9 Ω
7 (the classic value)52.4 Hz−6.8 dB27.5 Ω and 25.5 Ω
554.9 Hz−7.4 dB26.2 Ω and 23.9 Ω
360.4 Hz−8.6 dB23.8 Ω and 21.1 Ω
Impedance
10203050100200300500051015202530ΩHz
EnclosurePeak
Ported, QB328.6 Ω@ 19.0 Hz
Impedance
1020305010020030050051015202530ΩHz
EnclosurePeak
Ported, QB328.6 Ω@ 19.0 Hz
Impedance with Ql 10: two peaks (19 Hz and 73 Hz) and the dip at the tuning between them.
Impedance
10203050100200300500051015202530ΩHz
EnclosurePeak
Ported, QB326.2 Ω@ 19.0 Hz
Impedance
1020305010020030050051015202530ΩHz
EnclosurePeak
Ported, QB326.2 Ω@ 19.0 Hz
The same box with Ql 5: the dip stays at the tuning, but both peaks come down.

Going from a nearly perfect box (Ql 100) to a typical one (Ql 7–10) raises the F3 by 4–6 Hz and costs about 1 dB around the tuning. Even a leaky box (Ql 5) keeps its tuning frequency. Losses change how much the port helps, not where it tunes.

The other two losses, for comparison (with Ql 10):

LossesF3What changes
Ql 10, Qa 100, Qp 10050.6 HzThe reference
Absorption Qa 10 (heavily stuffed)58.4 HzThe upper impedance peak drops sharply (to 19.8 Ω)
Port Qp 10 (a lossy port)52.9 HzThe lower impedance peak drops (to 21.4 Ω); less port output

How to measure your box's losses

The losses show up most clearly in the impedance curve: more loss means lower peaks, while the dip stays at the tuning. Small described a full method for working out QL, QA and QP from impedance measurements [4]. In practice, there's an easier way with a simulator:

  1. Measure your box's impedance (DATS, REW, ARTA or similar) at a low level, after measuring the driver's own T/S parameters.
  2. Load the measurement (.zma) into the app: Add a measured impedance in the Impedance chart's menu (on a phone, Open / Import), and look at the Impedance chart.
  3. Adjust Leak Ql in Settings → Simulation → Box until the simulated peaks are the same height as the measured ones. If the upper peak is too high and the lower one about right, lower Absorb Qa instead; if it's the lower peak, lower Port Qp.
  4. Keep those values for that box: the simulation now includes its real losses.

Fit the driver's parameters first: an error in the driver's Qms looks just like box losses on an impedance curve.

Sealed boxes

A sealed box can't use a port's resonance, so its losses matter less, but they're not zero: leakage lowers its output at the bottom a little. In the app the same Ql applies: for the DSA215-8's sealed box, Ql 10 instead of 100 moves the F3 from 75 Hz to 79 Hz. Stuffing in a sealed box mostly makes it act a little larger (and raises its losses), which is why stuffed sealed boxes are often simulated as larger than they are. How much larger, and how to model and measure it, is in the box stuffing guide.

VituixCAD's Qa also makes the box act larger (+1.4 % at Qa 100, +11.3 % at Qa 10). Settings → Simulation → Box → Absorption, or Settings → General → Match → VituixCAD, does the same.

What to use

Open the example with Ql 10 → Open it with Ql 5 →

Sources

  1. R. H. Small, "Vented-Box Loudspeaker Systems, Part I: Small-Signal Analysis", J. Audio Eng. Soc. 21 (5), 363–372, June 1973: the QL, QA and QP losses and their effect on response and efficiency. AES E-Library.
  2. Claus Futtrup (SEAS), Designing Loudspeaker Boxes: the history of QL = 7 as a starting value, Beranek's box Q calculations, and leakage in the drivers themselves.
  3. Neville Thiele, The loudspeaker parameters and their evolution, Proceedings of the Institute of Acoustics 31 (4), 2009: QL has a small effect in vented designs, remedied by a somewhat larger box and slightly higher QT.
  4. R. H. Small, "Vented-Box Loudspeaker Systems, Part IV: Appendices", J. Audio Eng. Soc. 21 (8), 635–639, October 1973: evaluating leakage, absorption and vent losses from impedance measurements. AES E-Library.
  5. Speaker Box Genius validation against WinISD, including a ported box with leakage Ql 7.